Summary

Protection Against Electric Shock is a core element of safety for specifiers, designers, contractors and inspectors. Important changes affecting Guidance Note 5 include but are not limited to changes to earth fault loop impedances for all protective devices.

Guidance Note 5: Protection Against Electric Shock Summary

Guidance Note 5: Protection Against Electric Shock by The Institution of Engineering and Technology

Protection Against Electric Shock is a core element of safety for specifiers, designers, contractors and inspectors. Important changes affecting Guidance Note 5 include but are not limited to changes to earth fault loop impedances for all protective devices.

Make sure you are up to date with the changes and working to new standards in safety.

Amendment 3 published on 5 January 2015 and comes into effect on 1 July 2015. All new installations from this point must comply with Amendment 3 to BS 7671:2008.

Table of Contents

  • Chapter 1: Statutory Regulations and The Wiring Regulations
  • Chapter 2: Electric shock and protective measures
  • Chapter 3: Provisions for basic protection
  • Chapter 4: Automatic disconnection of supply
  • Chapter 5: Double or reinforced insulation
  • Chapter 6: Electrical separation
  • Chapter 7: Extra-low voltage provided by SELV or PELV
  • Chapter 8: Additional protection
  • Chapter 9: Obstacles and placing out of reach
  • Chapter 10: Protective measures for application only where the installation is controlled or under the supervision of skilled or instructed persons
  • Chapter 11: Earthing
  • Chapter 12: Circuit protective conductors
  • Chapter 13: Protective equipotential bonding
  • Chapter 14: Protective multiple earthing
  • Chapter 15: Special installations or locations
  • Chapter 16: Cables installed in walls, floors, ceilings and partitions
  • Appendix A: Maximum permissible measured earth fault loop impedance
  • Appendix B: Resistance of copper and aluminium conductors

Additional information

GOR009920763
9781849198776
1849198772
Guidance Note 5: Protection Against Electric Shock by The Institution of Engineering and Technology
Used - Very Good
Paperback
Institution of Engineering and Technology
20150306
136
N/A
Book picture is for illustrative purposes only, actual binding, cover or edition may vary.
This is a used book - there is no escaping the fact it has been read by someone else and it will show signs of wear and previous use. Overall we expect it to be in very good condition, but if you are not entirely satisfied please get in touch with us

Customer Reviews - Guidance Note 5: Protection Against Electric Shock